Product Name: DeepSeal 50S
Issue Date: May 2008
   
  Not Classified as Hazardous according to criteria of NOHSC
 

COMPANY DETAILS

Company Name: Know-How Waterproofing Pty Ltd (ABN 14 101 886 051)
Address P.O Box 775 Archerfield QLD 4108
Tel/Fax 07 - 32741000 / 07 - 32741006

 
IDENTIFICATION
 
Product Name DEEPSEAL “50S”
Shipping name   None allocated
UN Number 1307
Dangerous goods class IMO Class 3.3 Class 3
Packing group None allocated
Haz-chem Code  3YE
Poisons Schedule  IMO First Aid Guide Number 310
Chemical family Siloxane in aronatic hydrocarbon
Product Use Concrete and masonry preserver
   
PYSICAL DATA
 
Appearance Colourless liquid (may be coloured with inert pigments)
Melting Point  Not available
Boiling point 138 to 144 C
Vapour Pressure [mm of Hg at 25 c]: 10
Specific Gravity  0.9
Flash Point  24 c – Closed Up
Flamm. Limit LEL  0.6 to 7
Solubility in Water   Dispersible
 
FIRE AND EXPLOSION HAZARD DATA
 
Fire Extinguisher Media  Flammable liquid, Vapour may form explosive mixtures with air. Do not smoke.
Special Fire Fighting Procedures Call fire brigade. Use vapourising liquid, dry Chemical, carbon dioxide or alcohol form Extinguisher. Prevent run off entering drain.
Unusual Fire and Explosion Hazards Vapour may ignite on pumping or pouring due To static electricity. Keep away from sources of ignition.
Hazardous Products of Combustion  
 
HAZARDOUS INGREDIENTS
 
Ingredients  Name CAS Properties
  Siloxane   Low
  Methyleacrylate    low
  Hydrocarbon solvent 1330-20.7 High (60%)
 
HEALTH HAZARD INFORMATION
 
THRESHOLD LIMIT VALUE TLV 435 MG/M3
Acute  
Chronic  
 
FIRST AID
 
Acute - Swallowed Ingestion of this product may irritate the gastric tract, causing nausea and vomiting
Acute - Eye  Hold eye open and immediately wash with running water for 15 minutes. Remove all contaminated clothing including footwear. Wash affected areas with water and if available, soap.
Acute - Skin Wash affected areas with water and if available, soap.
Acute - Inhaled   Remove patient to fresh air and rest. If not breathing clear airway and apply artificial respiration. Keep warm and transport to doctor or hospital.
Chronic Prolonged or repeated skin contact may cause irritation and eventually dermatitis.
 
REACTIVITY DATA
 
Stability; (Conditions to avoid)
During transport, Handling and
Storage;

Keep containers tightly sealed. Keep away from heat or sources of ignition do not store in pits or basements where vapour may collect.

   
SPILL OR LEAK PROCEDURES
   
If Material is Released or Spilled:

Keep all sources of ignition away.
Avoid contact with eyes.Wear PVC Gloves, goggles and suitable respirator or air supplied helmet. Do not allow Spills to enter drains or sewers. Notify Police if this occurs.
Absorb spills with Vermiculite, sand or earth. Seal absorbed materials in labelled drums and consult local Waste Authority.

   
PERSONAL PROTECTION INFORMATION
 
Respiratory Protection:
Ventilation
Provide ventilation sufficient to maintain low level of vapour in workplace or Storage area. Keep all doors and Windows open and use forced ventilation to extract vapour from Confined spaces. Respiration required If not well ventilated.
Skin and eye protection Wear PVC gloves and goggles. Observe good industrial hygiene.
   
Every endeavour has been made to ensure that the information contained in this publication is reliable, but we shall not be liable for any inaccuracy in the information or for any loss, injury or damage whatsoever or however arising which may result from its use.
 